| Model | MC150M | MC150A | MC150AC |
|---|
| Balance Tank Capacity | 150 L (SUS316L, Electropolished) | 150 L (SUS316L, Electropolished) | 150 L (SUS316L, Electropolished) |
| Feeding Pump | N/A | N/A | 2 × Sanitary Centrifugal Pumps (VFD Control) |
| CIP Ball | Rotary Spray Type (360° Coverage) | Rotary Spray Type (360° Coverage) | Rotary Spray Type (360° Coverage) |
| Number of Balance Tanks | 1 | 1 | 1 |
| Delivery Flowrate | Max 60 LPM @ 2 bar | Max 60 LPM @ 2 bar | Max 60 LPM @ 2 bar |
| Valve Operation | Manual Butterfly Valves | Automatic Pneumatic Valves | Automatic Pneumatic Valves (PLC Integrated) |
| Delivery Pressure |
2 bar (Adjustable) |
2 bar (Adjustable) |
2 bar (Adjustable, Closed-loop Feedback) |
| Temperature Control |
Manual Rinse |
Semi-Auto Monitoring |
Fully Automatic PID Temperature Control |
| Delivery Temperature |
Ambient |
Ambient |
Ambient to 60°C (±1°C) |
| Temperature Sensor |
N/A |
RTD (PT100) |
RTD (PT100, PLC-linked) |
| Heating System |
N/A |
N/A |
Electric Heater (Stainless Enclosure, Safety Cutoff) |
| Conductivity Sensor |
N/A |
N/A |
0.2–600 µS/cm, 4–20 mA Output, PLC Feedback |
| Control System |
Manual Panel |
PLC (Semi-Auto Mode) |
PLC + HMI Touch Screen (Full Automation) |
| Material of Construction |
SUS316L (Inner Ra ≤ 0.6 µm) |
SUS316L (Inner Ra ≤ 0.6 µm) |
SUS316L (Inner Ra ≤ 0.6 µm) |
| Utility Requirements |
Power: 220V / Air: N/A |
Power: 220V / Air: 0.5 MPa |
Power: 220V / Air: 0.5 MPa |
| Optional Features |
Manual Operation Only |
Recipe Storage, Valve Auto Control |
Data Logging, Trend Graph, Alarm History |